Cypress AutoStore STK17T88 Specifikace Strana 9

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 24
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 8
STK17T88
Document Number: 001-52040 Rev. *C Page 9 of 24
AutoStore/Power Up RECALL
Figure 9. AutoStore Power Up RECALL
Notes
9. t
HRECALL
starts from the time V
CC
rises above V
SWITCH
10. If an SRAM WRITE has not taken place since the last nonvolatile cycle, no STORE will take place
11. Industrial Grade devices require 15 ms maximum.
No.
Symbols
Parameter
STK17T88
Units Notes
Standard Alternate Min Max
22 t
HRECALL
Power up RECALL Duration 40 ms 9
23 t
STORE
t
HLHZ
STORE Cycle Duration 12.5 ms 10, 11
24 V
SWITCH
Low Voltage Trigger Level 2.65 V
25 V
CCRISE
V
CC
Rise Time 150 μS
Note Read and Write cycles are ignored during STORE, RECALL, and while V
CC
is below V
SWITCH
25
23 23
22
22
Not Recommended for New Designs